Lutron TM 958 INFRARED THERMOMETER

Lutron TM 958 INFRARED THERMOMETER

FEATURES

 

* Infrared thermometer, non-contact temperature measurement, -30 to 300 ℃

  ( -22 to 572 ℉ ),precision for none contact temperature measurement.

* Emissivity value can adjust from 0.2 to 1.00.

* Back light LCD display.

* LCD display both temperature and the emissivity value.

* Microcomputer circuit with high performance.

* Wide temperature measuring range.

* Measurement via one operation button, easy to operate.

* 0.5 degree display resolution.

* Auto power shut off saves battery life.

* Built-in low battery indicator.

* Build in ℃ & ℉ select switch.

* Laser target guide for IR thermometer.

* Compact housing case with stand.

* Automatic data hold.

* 0.95 default emissivity value.

* Operates from 006P DC 9V battery.

 

GENERAL SPECIFICATIONS

Display  LCD, 29 mm x 33 mm. 
* Main display to show temp. value. 
* Lower display to show emissivity value. 
* Back Light. 
Sampling Time  Approx. 0.6 second. 
Hold and  After release the operation switch, 
Auto Power  display will hold the last measuring 
Off function  value within 5 seconds continuously. 
Functions ℃, ℉,
Auto data hold, 
Auto power off, 
Auto LCD back light, 
Emissivity adjustment. 
Over Indication  ≧ 305 , display will show 350℃ and flashed 
≦ -30 , display will show -30 and flashed
Power Supply  DC 9V battery, 006P, MN1604 ( PP3 ) 
or equivalent, heavy duty or Alkaline. 
Power Consumption  Approx. DC 14 mA, with laser light out. 
Approx. DC 25 mA, w/o laser light out.
Measurement Range  (-30 to 300℃) ( -22 to 572 ℉ )
Operating  0 to 50 (32 to 122 ).. 
Temp. and  Less than 80% RH. Resolution 0.5 /0.5 .. 
Humidity   
Circuit  Exclusive microcomputer circuit. 
Emissivity Adjustment Adjustment range : 0.20 to 1.00. 
* 0.95 default emissivity value. 
Weight  140 g/0.3 LB ( without battery ). 
Dimension  160 x 92 x 45 mm. 
( 6.3 x 3.6 x 1.8 inch ). 
Target Guide  * Less than 1 mW. 
* Class 2 laser diode. Red. Wave length 
  is 645 nm approximately. 
Standard Accessory  Operational manual..... 1 PC. 


ELECTRICAL SPECIFICATIONS

Measurement Range (-30 to 300℃) ( -22 to 572 ℉ )
Temp. Sensor  Thermocouple pie. 
Emissivity Setting  * By push button. Setting range : 0.20 to 1.00. 
* The default emissivity value is 0.95, 
   which will cover 90% of a typical application. 
Resolution  0.5 ℃/0.5 ℉.
Accuracy  ± 3 % of reading or ± 3 ( 5 ), which. 
ever is greater. 
*Meter operating temp. within 23±5 . 
  and the emissivity value of 
  measurement target set to 0.95. 
*Spec. tested under the 20 cm dia. 
 black body, the measuring distance 
 from the probe sensing Head is 30 cm. 
Measurement  6 to 12 micro meter. 
Wave length 
Region 
Distance Factor  D/S : Approx. 7:1. 
D - Distance, S - Spot.